1000 KVA Cast Resin Dry Type Transformer

1000 KVA Cast Resin Dry Type Transformer

Primary Voltage:11KV
Secondary Voltage:0.33KV
Power Rating: 1000 KVA
Connection Type: Dyn11/Yyno or others
Transformer Type: Dry Type Transformer
Standards: ANSI/IEEE, CSA/CAN, DOE
Certificate: UL, cUL, CSA, SGS,CE

Application

1000 KVA Cast Resin Dry Type Transformer are oil-free, reducing fire risks and environmental pollution, and are therefore particularly suitable for places with high fire protection requirements, such as medical institutions, educational institutions, data centers, renewable energy facilities, and special environments, to ensure safe and stable power supply.

Advantages of 1000 KVA Cast Resin Dry Type Transformer

Cast Resin Dry Type Transformer Series is a type of transformer characterized by low noise, low loss, and low partial discharge. This series of products feature reasonable structure, high-quality materials, scientific design, rigorous craftsmanship, advanced testing methods, and the following characteristics:

1.Explosion-proof, non-explosive, non-polluting, and no toxic gases.

2.High moisture resistance, capable of safe operation in harsh environments with 100% humidity without the need for dehumidification procedures.

3.Strong resistance to short-circuit.

4.Strong overload capacity, capable of operating at 110% rated load during AF, and 150% rated load.

5.Beautiful appearance, compact size, and low installation cost.

6.Performance and parameters meet or exceed GB, IEC, or industry standards.

Discover more about 1000 KVA Cast Resin Dry Type Transformers. Uni, as a leading transformer factory in China, is eager to share further details with you.

Specifications

Technical Characteristics of 1000 KVA Cast Resin Dry Type Transformer

ItemData
Aplicationphotovoltaic
Typeinsulating mineral oil ,according to standard IEC 60296
Cooling methodONAN
InstallationOutdoor / Indoor
Primary nominal voltage34.5 KV (available 13.2KV, 13.8KV 15KV ,11KV..)
Secondary nominal voltage800 V
Frequency60 Hz
connection groupDyn11 Yn11 (secondary double winding)
LossesReduced
Max. losses in empty (no load)BK36B036
Max losses in loadBK36B036
Tapping changer± 2 x 2.5% , manual
short-circuit impedance0.06
classA
CorrosionC 4
Electrostatic screen between MT/BTYes, connect to ground
DV/DT500V /us
MT side connectionby angled plug-in terminals
BT side connectionthrough terminals on copper plate
Connection protections MT sidemetal drawer cover for outdoor IP55 (Optional)
Connection protections BT sideIP55 metal outdoor cover drawer with cable glands for BT cable entry (optional)
Cuba oil collection and filteroptional
wheelsyes
lifting lugsyes
filling arrangement oil and drainageyes
communication and controlDGPT2 digital output signals
product warranty≥ 2 years

 

Parameter

Voltage Level of 1000 KVA Cast Resin Dry Type Transformer

Voltage Level of 1000 KVA Cast Resin Dry Type Transformer

Rated capacityVoltage ratioVector groupNo-load losses(kw)Impedance
10kva110v/220v/400v/3kvDyn11/Yd11/Yyno0.080.04
50kva380v/3kv/6kv/11kv/33kvDyn11/Yd11/Yyno0.130.04
100kva380v/3kv/6kv/11kv/33kvDyn11/Yd11/Yyno0.20.04
200kva380v/3kv/6kv/11kv/33kvDyn11/Yd11/Yyno0.340.04
500kva380v/3kv/6kv/11kv/33kvDyn11/Yd11/Yyno0.680.04
1000kva380v/3kv/6kv/11kv/33kvDyn11/Yd11/Yyno1.150.045
2500kva380v/3kv/6kv/11kv/33kvDyn11/Yd11/Yyno2.310.045
3.5mva380v/3kv/6kv/11kv/33kvDyn11/Yd11/Yyno2.730.045
24mva11kv/35kv/69kv/110kv/220kv/400kvDyn11/Yd11/Yyno
100mva11kv/35kv/69kv/110kv/220kv/400kvDyn11/Yd11/Yyno

PDF Download

PDF Download

Why Choose Us

Contact Us Immediately

hot-sale product

Series: SCB12
Application: Distribution Transformer
Country of Origin: China
Certifications: ISO9001, CB, CE, KEMA

Applications:

Urban Areas

Power Distribution

Heavy Industry

Railway Stations and Airports

Phase : 3 phases

Primary voltage: 10kV

Contact Us Immediately