1000 KVA Cast Resin Dry Type Transformer

1000 KVA Cast Resin Dry Type Transformer

Primary Voltage:11KV
Secondary Voltage:0.33KV
Power Rating: 1000 KVA
Connection Type: Dyn11/Yyno or others
Transformer Type: Dry Type Transformer
Standards: ANSI/IEEE, CSA/CAN, DOE
Certificate: UL, cUL, CSA, SGS,CE

Application

1000 KVA Cast Resin Dry Type Transformer are oil-free, reducing fire risks and environmental pollution, and are therefore particularly suitable for places with high fire protection requirements, such as medical institutions, educational institutions, data centers, renewable energy facilities, and special environments, to ensure safe and stable power supply.

Advantages of 1000 KVA Cast Resin Dry Type Transformer

Cast Resin Dry Type Transformer Series is a type of transformer characterized by low noise, low loss, and low partial discharge. This series of products feature reasonable structure, high-quality materials, scientific design, rigorous craftsmanship, advanced testing methods, and the following characteristics:

1.Explosion-proof, non-explosive, non-polluting, and no toxic gases.

2.High moisture resistance, capable of safe operation in harsh environments with 100% humidity without the need for dehumidification procedures.

3.Strong resistance to short-circuit.

4.Strong overload capacity, capable of operating at 110% rated load during AF, and 150% rated load.

5.Beautiful appearance, compact size, and low installation cost.

6.Performance and parameters meet or exceed GB, IEC, or industry standards.

Discover more about 1000 KVA Cast Resin Dry Type Transformers. Uni, as a leading transformer factory in China, is eager to share further details with you.

Specifications

Technical Characteristics of 1000 KVA Cast Resin Dry Type Transformer

Item Data
Aplication photovoltaic
Type insulating mineral oil ,according to standard IEC 60296
Cooling method ONAN
Installation Outdoor / Indoor
Primary nominal voltage 34.5 KV (available 13.2KV, 13.8KV 15KV ,11KV..)
Secondary nominal voltage 800 V
Frequency 60 Hz
connection group Dyn11 Yn11 (secondary double winding)
Losses Reduced
Max. losses in empty (no load) BK36B036
Max losses in load BK36B036
Tapping changer ± 2 x 2.5% , manual
short-circuit impedance 0.06
class A
Corrosion C 4
Electrostatic screen between MT/BT Yes, connect to ground
DV/DT 500V /us
MT side connection by angled plug-in terminals
BT side connection through terminals on copper plate
Connection protections MT side metal drawer cover for outdoor IP55 (Optional)
Connection protections BT side IP55 metal outdoor cover drawer with cable glands for BT cable entry (optional)
Cuba oil collection and filter optional
wheels yes
lifting lugs yes
filling arrangement oil and drainage yes
communication and control DGPT2 digital output signals
product warranty ≥ 2 years

 

Parameter

Voltage Level of 1000 KVA Cast Resin Dry Type Transformer

Rated capacity Voltage ratio Vector group No-load losses(kw) Impedance
10kva 110v/220v/400v/3kv Dyn11/Yd11/Yyno 0.08 0.04
50kva 380v/3kv/6kv/11kv/33kv Dyn11/Yd11/Yyno 0.13 0.04
100kva 380v/3kv/6kv/11kv/33kv Dyn11/Yd11/Yyno 0.2 0.04
200kva 380v/3kv/6kv/11kv/33kv Dyn11/Yd11/Yyno 0.34 0.04
500kva 380v/3kv/6kv/11kv/33kv Dyn11/Yd11/Yyno 0.68 0.04
1000kva 380v/3kv/6kv/11kv/33kv Dyn11/Yd11/Yyno 1.15 0.045
2500kva 380v/3kv/6kv/11kv/33kv Dyn11/Yd11/Yyno 2.31 0.045
3.5mva 380v/3kv/6kv/11kv/33kv Dyn11/Yd11/Yyno 2.73 0.045
24mva 11kv/35kv/69kv/110kv/220kv/400kv Dyn11/Yd11/Yyno
100mva 11kv/35kv/69kv/110kv/220kv/400kv Dyn11/Yd11/Yyno

PDF Download

PDF Download

Why Choose Us

Contact Us Immediately

hot-sale product

Applications:

Urban Areas

Power Distribution

Heavy Industry

Railway Stations and Airports

Phase : 3 phases

Primary voltage: 10kV

Factory-direct supply and competitive price
Full range of oil-immersed & dry-type transformers
Reliable performance, certified by CE and ISO
Professional export experience to 40+ countries

Contact Us Immediately